Air Cleaner Housing - Honda C8R600F4 Service Manual

Table of Contents

Advertisement

FUEL SYSTEM
AIR CLEANER HOUSING
REMOVAL/INSTALLATION
Remove the fuel tank (page 2-3).
California type
Remove the evaporative emission (EVAP) purge
only:
control valve from the air cleaner housing.
Remove the wire harness clip from the air cleaner
housing.
Be careful not to
Disconnect the four vacuum tubes and secondary
break the plastic
air supply hose (California: No.
15).
plugs.
5-14
Disconnect the crankcase breather hose from the
air cleaner housing.
loosen the two connecting tube band screws of
the air intake ducts.
Loosen the fom connecting tuhe
band
scrnws.
Remove the air cleaner housing off the carburetor
intake ports and air intake ducts.
Disconnect the float chamber inner air vent hose
(California: No. 7) and the vacuum chamber air vent
hose.
Installation is in the reverse order of removal.
. - - - - - - - - - - - - - - .