System Data
System-Specific Capacity Limits for HiPath 3000, HiPath 5000
1
Testing is not required on stations and lines up to the maximum configuration. Testing using the project planning tool is
mandatory for configurations which include UCD/ACD, more than one SLCN, or groups of more than 10 stations (intranet:
http://intranet.mch4.siemens.de/syseng/perfeng/tools/hpt/index.htm).
2
Only configurations that do not exceed this limit will be supported.
3
Depending on the system configuration and performance, the specified capacity limits may not always be achieved. To
ensure that the dynamic capacity limit of HiPath 3750 or HiPath 3700 is not exceeded, the configuration can be tested
using the project planning tool (intranet: http://intranet.mch4.siemens.de/syseng/perfeng/tools/hpt/index.htm). Testing is
not required for configurations of up to 250 stations and 90 lines. Testing using the project planning tool is mandatory for
configurations which include UCD/ACD, more than one SLC16/SLC16N, or groups of more than 10 stations.
4
Up to 96 of the 192 stations can be TDM stations.
5
Up to 61 of the 192 stations can be TDM stations (4xa/b + 1xU
tral board + 3xSLU8R or 3x8SLAR).
6
Up to 41 of the 96 stations can be TDM stations (4xa/b + 5xU
board + 1x16SLA).
7
Up to 33 of the 96 stations can be TDM stations (4xa/b + 5xU
board + 1xSLU8R or 1x8SLAR).
8
These are administrative capacity limits.
9
Due to the power consumption of HG 1500, a UPSC-D must be used.
10 Due to the power consumption of HG 1500, a UPSC-DR must be used.
11 If the total number of U
72, an external EPSU2 power supply unit must be used.
12 4xa/b + 1xU
+ 7xBS/32xHiPath Cordless Office stations at the central board + 5xSLU8R or 5x8SLAR.
P0/E
13 4xa/b + 5xU
+ 3xBS/16xHiPath Cordless Office stations at the central board + 2x16SLA.
P0/E
14 4xa/b + 5xU
+ 3xBS/16xHiPath Cordless Office stations at the central board + 2xSLU8R or 2x8SLAR.
P0/E
15 Testing using the project planning tool is not required for configurations of up to 384 analog stations, no other station types,
and 90 lines. Configurations that contain UCD/ACD or more than one SLC16/SLC16N or groups with more than ten sta-
tions should always be checked using the project planning tool (intranet:
tools/hpt/index.htm).
16 4xa/b at the central board + 5x8SLAR.
17 4xa/b at the central board + 2x16SLA.
18 4xa/b at the central board + 2x8SLAR.
19 8xU
at the central board + 5xSLU8 + 1xSLMO24.
P0/E
20 8xU
at the central board + 5xSLU8R.
P0/E
21 8xU
at the central board + 2xSLU8.
P0/E
22 8xU
at the central board + 2xSLU8R.
P0/E
23 The total number of U
24 If the total number of U
UPSC-DR must be used.
25 Due to the 5-V power supply unit, one SLC16/SLC16N and a maximum of two HG 1500 V3.0 boards can be used.
26 64 HiPath Cordless Office stations at the SLC16/SLC16N or 32 HiPath Cordless Office stations at the central board.
27 Two HG 1500 boards can be installed if PDM1 is not being used.
2-22
stations, analog stations and additional stations connected using an adapter is greater than
P0/E
stations and additional stations connected using an adapter is limited to 384.
P0/E
stations and additional stations connected using an adapter is greater than 24, a UPSC-D/
P0/E
+ 7xBS/32xHiPath Cordless Office stations at the cen-
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central
P0/E
http://intranet.mch4.siemens.de/syseng/perfeng/
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual