on the flywheel. Incorrect installation may
result in the CKP sensor being damaged.
NOTE: Make sure that the CKP sensor
housing is clean and free from foreign
material.
Install the CKP sensor.
3. Install the CKP sensor retaining bolt.
4. Connect the CKP sensor electrical connector.
5. Install the CKP sensor against the flywheel.
6. Using suitable feeler gauges, take note of the
measurement of the gap between the CKP sensor
and the CKP sensor housing.
7. Set the CKP sensor gap to the flywheel.
1. Add 1.2 mm to the measurement recorded
in step 11. Using suitable feeler gauges set
to the calculated figure, set the gap
between the CKP sensor and the CKP
sensor housing.
2. Finger tighten the CKP sensor bolt.