D6: CHECK THE CIRCUIT BETWEEN THE AIR RECIRCULATION FLAP ACTUATOR AND
THE CONTROL PANEL FOR THE CLIMATE CONTROL SYSTEM FOR OPEN CIRCUIT - RHD
VEHICLES BUILT FROM 08/2004
D7: CHECK THE CIRCUIT BETWEEN THE AIR RECIRCULATION FLAP ACTUATOR AND
THE CONTROL PANEL FOR THE CLIMATE CONTROL SYSTEM FOR OPEN CIRCUIT - RHD
VEHICLES BUILT FROM 08/2004
D8: CHECK THE CIRCUIT BETWEEN THE AIR RECIRCULATION FLAP ACTUATOR AND
THE CONTROL PANEL FOR THE CLIMATE CONTROL SYSTEM FOR SHORT TO VOLTAGE
LOCATE and REPAIR the break in circuit 33-FA76
(YE/BU) between the air recirculation flap actuator
and the control panel for the climate control
system with the aid of the Wiring Diagrams. CHECK
the operation of the system.
Ignition switch in position 0.
1
Disconnect Connector C380 from the control panel
2
for the climate control system.
Measure the resistance between the recirculated
3
air flap actuator, connector C375, pin 2, circuit 33-
FA76R (YE/BU), wiring harness side and the control
panel for the climate control system, connector
C380, pin 16, circuit 33-FA76R (YE/BU), wiring
harness side.
Is a resistance of less than 2 Ohm registered?
Yes
GO to
D7.
No
LOCATE and REPAIR the break in circuit 33-FA76R
(YE/BU) between the air recirculation flap actuator
and the control panel for the climate control
system with the aid of the Wiring Diagrams. CHECK
the operation of the system.
Measure the resistance between the recirculated
1
air flap actuator, connector C375, pin 4, circuit 32-
FA76R (WH/BU), wiring harness side and the
control panel for the climate control system,
connector C380, pin 14, circuit 32- FA76R (WH/BU),
wiring harness side.
Is a resistance of less than 2 Ohm registered?
Yes
GO to
D8.
No
LOCATE and REPAIR the break in circuit 32-FA76R
(WH/BU) between the air recirculation flap actuator
and the control panel for the climate control
system with the aid of the Wiring Diagrams. CHECK
the operation of the system.
Ignition switch in position II.
1
Measure the voltage between the control panel for
2
the climate control system, connector C380, pin
16, circuit 33-FA76 (YE/BU) (RHD vehicles: circuit
33-FA76R (YE/BU)), wiring harness side and
ground.