Climate Control System - General
Information - Air Conditioning (A/C)
System Recovery, Evacuation and
Charging
General Procedures
General Equipment
Refrigerant center
Refrigerant analyzer
Transit/Tourneo Connect 2002.5 (06/2002-)
1.
CAUTION: The refrigerant analyzer must
be used before recovery, otherwise the
refrigerant center may become
contaminated. Contaminated refrigerant
must be disposed of as hazardous waste.
Always follow the manufacturer's instructions
when using the refrigerant center and the
refrigerant analyzer.
Remove the protective cap from the A/C high-
pressure charging connection.
2. Detach the right-hand wheel arch trim panel
(shown with wheel removed for clarity).
3. Remove the protective cap from the A/C low-
pressure charging connection.
4. Pull back the catches of the quick-fit unions on
the refrigerant center lines.
NOTE: Larger inner diameter for high-
5.
pressure side. Smaller inner diameter for
low-pressure side.
Connect the refrigerant center lines to the A/C
charging connections.
http://vnx.su