evacuate the fuel tank.
8.
NOTE: Before any work can be carried out on
the LPG fuel tank, make sure the pressure
gauge on the LPG recovery equipment is at 0
bar. Failure to follow this instruction may
result in personal injury.
Loosen the PRV adaptor special tool lift nut (LPG
recovery and transfer unit fuel line connector
shown disconnected for clarity).
9.
WARNING: The LPG recovery equipment
must be operated in accordance with the
manufacturer's operating instructions. Failure
to follow this instruction may result in
personal injury.
Turn off the LPG recovery and transfer unit
equipment.
WARNING: Always disconnect the
10.
recovery equipment fuel line from the vehicle
before proceeding to the next step. Failure to
follow this instruction may result in personal
injury.
Disconnect the LPG recovery and transfer unit
from the fuel line connector special tool.
Disconnect the LPG recovery and transfer
unit ground cable from the vehicle.
NOTE: Make sure the PRV lift nut is
11.
positioned next to the PRV locking nut before
removal.
Loosen the PRV adaptor special tool locking nut
and remove the PRV adaptor special tool.
12. Remove the fuel line connector special tool from
the PRV adaptor special tool.