Ford Transit 2002 Owner's Manual page 1502

Table of Contents

Advertisement

Climate Control System - General
Information - Refrigerant Oil Adding
General Procedures
CAUTION: Collect the refrigerant oil in a clean measuring cylinder.
Transit/Tourneo Connect 2002.5 (06/2002-)
NOTE: This step only needs to be carried out
1.
when replacing the A/C compressor.
NOTE: Rotate the compressor shaft at least 6
to 8 turns when draining the refrigerant oil.
Drain the refrigerant oil from the defective A/C
compressor and dispose of it.
CAUTION: If the refrigerant oil is not to
2.
be reused within 15 minutes of draining it
from the new compressor, store it in a closed
and sealed container to prevent ingress of
moisture.
NOTE: The refrigerant oil from the new A/C
compressor needs to be drained because the
fill capacities at the factory are not always
the same.
NOTE: Rotate the compressor shaft at least 6
to 8 turns when draining the refrigerant oil.
Drain the refrigerant oil from the new A/C
compressor.
3.
CAUTIONS:
The amount of refrigerant oil topped up
must not exceed the refrigerant oil fill
capacity.
If other A/C components are being
renewed in addition to the A/C compressor,
there is no need to top up with additional
refrigerant oil, apart from filling the
compressor.
Add the calculated quantity of new refrigerant oil.
See: Specifications (412-00 Heating, Ventilation,
Air-Conditioning - General information,
Specifications).