3. The starting logic figure of starting after the automatic fault reset

Relative parameters list:
Function
code
P00.01
P00.11
P00.12
P01.00
Starting frequency of
P01.01
P01.02
Retention time of the
Name
Running command
channel
ACC time 1
DEC time 1
Start method
direct start-up
Detailed instruction of parameters
0:Keypad running command
channel(LED light off)
1:Terminal running command channel
(LED flickering)
2:Communication
channel (LED on)
0.0~3600.0s
0.0~3600.0s
0:Start-up directly
1:Start-up after DC braking
2: Start-up after rotation speed tracking 1
0.00~50.00Hz
0.0~50.0s
169
Basic operation instruction
running
command
Default
value
1
Depend
on model
Depend
on model
0
0.50Hz
0.0s