inverters
Goodrive300
Set
value
23
Simple PLC stop reset
24
Simple PLC pause
25
PID control pause
Traverse pause (stop at the
26
current frequency)
Traverse reset (return to the
27
middle frequency)
28
29
Torque control enabling
30
ACC/DEC disabling
31
32
increasing/decreasing setting
33
34
Shifting between motor1 and
35
36
Shift the command to the
Function
Counter reset
Counter trigging
Length reset
Frequency
temporal clear
DC braking
motor2
Restart simple PLC and clear the memory state of
PLC.
Program pause during PLC implement. Run at the
current speed stage. After cancel the function, simple
PLC continues to run.
Temporal PID invalid and the inverter will output at the
current frequency.
The inverter will stop at the current output and after
canceling the function, the inverter will continue to
traverse run at the current frequency.
The setting frequency of the inverter will come back to
the middle frequency.
Counter clear
The inverter shifts from torque control mode to speed
control mode.
Ensure the inverter will not be affected by the external
signals (except for the stopping command) and keep
the current output frequency.
Enable the pulse counter.
Length counter clear
When the terminal closes, the frequency set by
UP/DOWN can be cleared. All set frequency will be
restored into the given frequency by the frequency
command channel and the frequency will come back
to the value after the frequency increasing or
decreasing.
The inverter will begin DC braking after the valid
command.
Motor-shifting can be controlled after the terminal is
valid.
After the function terminal become valid, the running
187
Basic operation instruction
Instructions