Functio
Name
n code
Carrier
P00.14
frequency
setting
Detailed instruction of parameters
some special cases if the reverse running is
disabled.
The relationship table of the motor type and carrier
frequency:
Motor type
1.5~11kW
15~55kW
Above
75kW
The advantage of high carrier frequency: ideal
current waveform, little current harmonic wave and
motor noise.
The disadvantage of high carrier frequency:
increasing the switch loss, increasing inverter
temperature and the impact to the output capacity.
The inverter needs to derate on high carrier
frequency. At the same time, the leakage and
electrical magnetic interference will increase.
Applying low carrier frequency is contrary to the
above, too low carrier frequency will cause unstable
running, torque decreasing and surge.
The manufacturer has set a reasonal carrier
frequency when the inverter is in factory. In general,
users do not need to change the parameter.
When the frequency used exceeds the default carrier
frequency, the inverter needs to derate 20% for each
The factory value of
carrier frequency
8kHz
4kHz