INVT Goodrive 300 Operation Manual page 85

Hide thumbs Also See for Goodrive 300:
Table of Contents

Advertisement

inverters
Goodrive300
Functio
Name
n code
HDI
terminal
P05.30
switching-on
delay time
HDI
terminal
P05.31
switching-off
delay time
Lower limit of
P05.32
AI1
Correspondi
ng setting of
P05.33
the lower
limit of AI1
Upper limit of
P05.34
AI1
Correspondi
ng setting of
P05.35
the upper
limit of AI1
AI1 input
P05.36
filter time
Lower limit of
P05.37
AI2
Correspondi
ng setting of
P05.38
the lower
limit of AI2
Upper limit of
P05.39
AI2
P05.40 Correspondi
Detailed instruction of parameters
The function code defines the relationship between
the analog input voltage and its corresponding set
value. If the analog input voltage beyond the set
minimum or maximum input value, the inverter will
count at the minimum or maximum one.
When the analog input is the current input, the
corresponding voltage of 0~20mA is 0~10V.
In different cases, the corresponding rated value of
100.0% is different. See the application for detailed
information.
The figure below illustrates different applications:
Input filter time: this parameter is used to adjust the
sensitivity of the analog input. Increasing the value
properly can enhance the anti-interference of the
analog, but weaken the sensitivity of the analog
input.
84
Function codes
Default
Modif
value
y
0.000s
0.000s
0.00V
0.0%
10.00V
100.0%
0.100s
0.00V
0.0%
10.00V
100.0%