inverters
Goodrive300
Functio
Name
n code
Dead time of
P01.13
FWD/REV
rotation
Shifting
between
P01.14
FWD/REV
rotation
Stopping
P01.15
speed
Detection of
stopping
P01.16
speed
Detection
P01.17
time of the
feedback
Detailed instruction of parameters
Setting range of P01.11: 0.0~150.0%
Setting range of P01.12: 0.0~50.0s
During the procedure of switching for/rev rotation,
set the threshold by P01.14, which is as the table
below:
Setting range: 0.0~3600.0s
Set the threshold point of the inverter:
0:Switch after 0 frequency
1:Switch after the starting frequency
2: Switch after the speed reach P01.15 and delay for
P01.24
0.00~100.00Hz
0: Speed setting (the only detection method in V/F
mode)
1: Speed detecting value
When the actual output frequency of the inverter is
lower than P01.15 and the lasting time is beyond
P01.17, the running state ends and the inverter
stops.
If set P01.16 to 1, the feedback frequency is less
than or equal to P01.15 and detect in the set time of
P01.17, the inverter will stop; otherwise the inverter
59
Function codes
Default
Modif
value
y
○
0.0s
◎
0
◎
0.50 Hz
◎
0
◎
0.05s
Need help?