inverters
Goodrive300
Functio
Name
n code
P08.03 DEC time 3
P08.04 ACC time 4
P08.05 DEC time 4
Jogging
P08.06
frequency
Jogging ACC
P08.07
time
Jogging DEC
P08.08
time
Jumping
P08.09
frequency 1
Jumping
P08.10
frequency
range 1
Jumping
P08.11
frequency 2
Jumping
P08.12
frequency
range 2
Jumping
P08.13
frequency 3
Detailed instruction of parameters
This parameter is used to define the reference
frequency during jogging.
Setting range: 0.00Hz ~P00.03(the Max. frequency)
The jogging ACC time means the time needed if the
inverter runs from 0Hz to the Max. Frequency.
The jogging DEC time means the time needed if the
inverter goes from the Max. Frequency (P0.03) to
0Hz.
Setting range:0.0~3600.0s
When the set frequency is in the range of jumping
frequency, the inverter will run at the edge of the
jumping frequency.
The inverter can avoid the mechanical resonance
point by setting the jumping frequency. The inverter
can set three jumping frequency. But this function
will be invalid if all jumping points are 0.