inverters
Goodrive300
Functio
Name
n code
Answer
P14.03
delay
Fault time of
P14.04
communicati
on overtime
Transmissio
P14.05
n fault
processing
Communicati
P14.06
on
processing
Detailed instruction of parameters
0: No check (N,8,1)for RTU
1:Odd check (E,8,1)for RTU
2:Even check (O,8,1)for RTU
3:No check (N,8,2)for RTU
4: Odd check (E,8,2)for RTU
5:Even check(O,8,2)for RTU
0~200ms
Mean the interval time when the drive receive the
data and sent it to the upper monitor. If the answer
delay is shorter than the system processing time,
then the answer delay time is the system processing
time, if the answer delay is longer than the system
processing time, then after the system deal with the
data, waits until achieving the answer delay time to
send the data to the upper monitor.
0.0(invalid),0.1~60.0s
When the function code is set as 0.0, the
communication overtime parameter is invalid.
When the function code is set as non-zero, if the
interval time between two communications exceeds
the communication overtime, the system will report
"485 communication faults" (CE).
Generally, set it as invalid; set the parameter in the
continuous communication to monitor the
communication state.
0:Alarm and stop freely
1:No alarm and continue to run
2:No alarm and stop according to the stop
means(only under the communication control)
3:No alarm and stop according to the stop
means(under all control modes)
0x00~0x11
LED ones:
0:Operation with response: the drive will respond to
132
Function codes
Default
Modif
value
y
○
5
○
0.0s
○
0
○
0x00