Example 2: Modify the parameter values (RAM and EEPROM are modified)
Modify keypad settings frequency value (the address of keypad set frequency is 4) which
can be achieved by setting PKW1 as 2; PKW2 as 4, modification value (50.00) is in PKW4.

Request (From master to inverter):

Requst

Response (From inverter to master)

Response
Example for PZD:
Transmission of PZD area is achieved through inverter function code; please refer to
relevant INVT inverter user manual to know relevant function code.
Example 1: Read process data of inverter
Inverter parameter selects "8: Run frequency" as PZD3 to transmit which can be achieved
by setting Pd.14 as 8. This operation is mandatory until the parameter is instead of others.
Request (From master to inverter):
PKW1 PKW2
Response xx xx xx xx xx xx
Example 2: Write process data into inverter
Inverter parameter selects "2": Traction given" from PZD3 which can be achieved by setting
Pd.03 as 2. In each request frame, parameters will use PZD3 to update until re-select a
parameter.
Request (From master to converter):
PKW1 PKW2 PKW3
PKW1 PKW2 PKW3 PKW4
00 01 00 04 00 00 50
0001: Reponse (Parameter values refreshed)
PKW1 PKW2 PKW3 PKW4
00 02 00 04 00 00 50
0004: Parameter changes
PKW1 PKW2 PKW3 PKW4
00 01 00 04 00 00 50
0001: Response (Parameter values refreshed)
PKW3
PKW4
xx
PKW4
CW PZD2 PZD3
00
xx
xx xx xx xx xx
5000: Address 4 parameter
CW PZD2 PZD3
00
xx
xx xx xx xx xx
5000: Address 4 parameter
CW PZD2 PZD3
00
xx
xx xx xx xx xx
CW
PZD2
xx
xx
xx
xx
xx
CW
PZD2
270
Appendix A
···
PZD12
xx xx
···
···
PZD12
xx xx
···
···
PZD12
xx xx
···
PZD3
...
PZD12
00
0A ...
xx
PZD3
...
PZD12
xx