UP terminals
frequency
P08.45
changing
ratio
DOWN
terminals
P08.46
frequency
changing
ratio
Action when
the
P08.47
frequency
setting is off
High bit of
P08.48
initial power
consumption
Low bit of
P08.49
initial power
consumption
Magnetic flux
P08.50
braking
Detailed instruction of parameters
0.01~50.00Hz/s
0.01~50.00 Hz/s
0x000~0x111
LED ones:The action selection when the digital
adjusting the frequency is off.
0:Save when the power is off
1:Clear when the power is off
LED tens:The action selection when MODBUS set
frequency is off
0:Save when the power is off
1:Clear when the power is off
LED hundreds:The action selection when the other
frequency set frequency is off
0:Save when the power is off
1:Clear when the power is off
This parameter is used to set the original value of the
power comsumotion.
The original value of the power comsumotion
=P08.48*1000+ P08.49
Setting range of P08.48: 0~59999°(k)
Setting range of P08.49:0.0~999.9°
This function code is used to enable magnetic flux.
0: Invalid.
1: Valid.