Managing Switch Software Using Edm - Avaya 4524GT Configuration Manual

Ethernet routing switch 4500 series
Table of Contents

Advertisement

System configuration using Enterprise Device Manager
Variable
Index
TrafficType
AllowedRate
Enable

Managing switch software using EDM

Use this procedure to change the binary configuration running on the switch, upload the
configuration file to a TFTP server or a USB storage device, or retrieve a binary configuration
file from a TFTP server.
Important:
When you use the TFTP address parameter to perform copy or download commands, the
system overwrites the TFTP server address
Procedure steps
1. From the navigation tree, double-click Edit.
2. In the Edit tree, double-click File System.
3. On the work area, click the Config/Image/Diag file tab.
4. In the TftpServerInetAddressType section, click a radio button.
5. In the TftpServerInetAddress dialog box, type the TFTP server IP address.
6. In the BinaryConfigFileName dialog box, type the name of the binary configuration
7. In the BinaryConfigUnitNumber dialog box, type a unit number.
8. In the ImageFileName dialog box, type the name of the current image file.
9. In the FwFileName(Diagnostics) dialog box, type the name of the current diagnostic
10. In the UsbTargetUnit dialog box, type a value.
11. In the Action section, click a radio button.
12. Click Apply.
240
Configuration — System
Indicates the unique identifier.
Specifies the two types of traffic that can be set with rate limiting:
broadcast and multicast.
Specifies the rate limiting percentage. The available range is from 0
percent (none) to 10 percent.
Enables and disables rate limiting on the port for the specified traffic
type. Options are true (enabled) or false (disabled).
file.
file.
Value
April 2011

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents