System configuration using Enterprise Device Manager
Procedure steps
1. From the navigation tree, double-click Edit.
2. In the Edit tree, double-click Diagnostics.
3. In the Diagnostic tree, double-click 802.1AB.
4. In the 802.1AB tree, double-click Port dot1.
5. On the work area, click the Neighbor Protocol tab.
Variable definitions
The following table describes the Neighbor Protocol tab fields.
TimeMark
LocalPortNum
Index
ProtocolIndex
ProtocolId
LLDP Port dot3 configuration using EDM
Use the information in this section to configure and view IEEE 802.3 LLDP information.
Viewing LLDP local port auto-negotiation information using EDM
Use the following procedure to display LLDP auto-negotiation properties for the local
system.
308
Configuration — System
Variable
Indicates the TimeFilter for this entry.
Indicates the local port on which the remote system
information is received.
Indicates the arbitrary local integer value used by this
agent to identify a particular MSAP. An agent is
encouraged to assign monotonically increasing index
values to new entries, starting with one, after each
reboot.
Represents an arbitrary local integer value used by
this agent to identify a particular protocol identity.
Indicates the protocols associated with the remote
port.
Value
April 2011