Viewing Poe For Multiple Switch Units Using Edm - Avaya 4524GT Configuration Manual

Ethernet routing switch 4500 series
Table of Contents

Advertisement

Variable
Notification
ControlEnable
PowerDevice
DetectType
PowerPresent

Viewing PoE for multiple switch units using EDM

Use this procedure to display the PoE configuration for one or more switches in a stack.
Procedure steps
1. From the navigation tree, double-click Power Management.
2. In the Power Management tree, double-click PoE.
3. In the work area, click the Globals - PoE Units tab.
Configuration — System
pethMainPowerUsageOnNotification trap. If the power
consumption exceeds and then falls below the threshold, the switch
sends the pethMainPowerUsageOffNotification trap.
Important:
You must enable the traps (NotificationControlEnable) to receive
a power usage trap.
Lets you enable or disable sending traps if the switch power usage
exceeds the percentage set in the UsageThreshold field.
Lets you set the power detection type that the switch uses to detect
a request for power from a device connected to all ports on the
switch:
• 802.3af
• 802.3af and legacy
Important:
The default setting is 802.3af. Ensure that this setting matches
the setting for the detection type used by the powered devices
on this switch.
Specifies the currently used power source. Available power
sources are AC and DC.
• A value of acOnly indicates that the only power supply is AC.
• A value of dcOnly indicates that the only power supply is DC.
• A value of acDc indicates that there are two power supplies; both
AC and DC are supplying power
Switch unit PoE management using EDM
Value
April 2011
217

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents