Dtc 45-1 (Neutral Oil Pressure Switch) - Honda NSA700A DN-1 2009 Service Manual

Table of Contents

Advertisement

HFT
3. EOT Sensor Line Open Circuit Inspection
Turn the ignition switch OFF.
Disconnect the jum per wire and TCM 33P (Black)
connector.
Check for continuity between the EOT sensor 2P
connector terminals and TCM 33P connector ter­
minals.
Connection: A27 (Green/black) - Green/black
TOOL:
Test probe
Is there c o n tin u ity ?
YES
NO
DTC 45-1 (NEUTRAL OIL PRESSURE
SWITCH)
• Before starting inspection. Check for loose or
poor connectors on the neutral oil pressure
switch wire terminals and TCM 33P (Black) con-
necto', then check the DTC.
1. Neutral Oil Pressure Switch Input Line Open
Circuit Inspection
Turn the ignition switch OFF.
Disconnect the TCM 33P (Black) connector.
Remove the bolt and disconnect the neutral oil
pressure switch wire terminals.
Connect the neutral oil pressure switch wire ter­
minals.
Check for continuity at the TCM 33P connector
terminals.
Connection: A26 (Yellow/red) - A29 (Yellow/
TOOL:
Test probe
Is there c o n tin u ity ?
YES
NO
11-54
B33 (Blue) - Blue
07ZAJ-RDJA110
- Replace the TCM w ith a new one, and
recheck (HFT initialization procedure:
page 11-93).
- • Open circuit in the Green/black wire.
• Open circuit in the Blue wire.
green)
07ZAJ-RDJA110
- GO TO STEP 2.
- • Open circuit in Yellow/red.
• Open circuit in Yellow/green.
TCM 33P (Black) CONMECTOR
(Wire side of female terminal)
(Wire side of female terminal)

Advertisement