Honda NSA700A DN-1 2009 Service Manual page 323

Table of Contents

Advertisement

5. Swash
Plate
Control
Inspection
Remove th" swash plate control motor (page 11-
97).
Check fo r continuity at the swash plate control
m otor connector terminals of the m otor side.
Is the re c o n tin u ity ?
YES
- GO TO STEP
NO
- Faulty swash plate control motor.
. Swash Plate Control M otor Operate Inspection
6
(Clockwise)
Apply battery voltage to the control motor 2P
connector terminals and check that the control
m otor operation.
Does the c o n tro l m o to r tu rn (C lockw ise)?
YES
- GO TO STEP 7.
NO
- Faulty control motor.
7. Swash Plate Control M otor Operate Inspection
(Counterclockwise)
Apply battery voltage to the control motor 2P
connector terminals and check that the control
m otor operation.
Does the c o n tro l m o to r tu rn (C ounterclock­
wise)?
YES
- Replace the TCM w ith a new one, and
recheck (HFT initialization procedure:
page 11-93).
NO
- Faulty control motor.
M otor
Continuity
.
6
MOTOR 2P (Black) CONNECTOR
(M otor side of male terminal)
MOTOR 2P (Black) CONNECTOR
(M otor side of male terminal)
MOTOR 2P (Black) CONNECTOR
(M otor side of male terminal)
HFT

Advertisement