2. Swash Plate Control
Inspection
Install the HFT m otor fuse 30 A.
Disconnect the TCM 5P (Black) connector.
Measure the voltage at the TCM connector ter­
minal of the wire harness side.
Connection: Red/yellow (+) - Green/White (-)
Does the b a tte ry voltage e x is t?
YES
NO
3. Swash Plate Control M otor Line Open Circuit
Inspection
Disconnect the swash plate control motor 2P
(Black) connector.
Check for continuity between the TCM 5P con­
nector terminals and the swash plate control
m otor 2P (Black) connector terminals of the wire
harness side.
CONNECTION: Red/black - Red/black
Is th e re c o n tin u ity ?
YES
NO
4. Swash Plate Control M otor Line Short Circuit
Inspection
Check fo r continuity between the TCM 5P con­
nector terminals of the wire harness side and
ground.
CONNECTION: Red/black - Ground
Is there co n tin u ity ?
YES
NO
11-46
M otor
- GO TO STEP 3.
- • Open circuit in Red/yellow and/or
Red/white wire.
• Open circuit in Green/white wire.
Yellow - Yellow
- GO TO STEP 4.
- • Open circuit in Red/black wire.
• Open circuit in Yellow wire.
Yellow - Ground
- • Short circuit in Red/black wire.
• Short circuit in Yellow wire.
- GO TO STEP 5.
Input Voltage
MOTOR 2P (Black) CONNECTOR
(Wire side of female terminal)
TCM 5P (Black) CONNECTOR
(Wire side of female terminal)
Red/black
Yellow
TCM 5P (Black) CONNECTOR
(Wire side of female terminal)