5.12.3.1

Requirements for SnMP Operation

5-140 Operation
Traps are configured in the snmp.xml file. A 'limit' and an 'operator' can
be defined for each possible managed object. If an OnAir 3000 subsystem
generates a user message, this may also generate a trap (including message
ID, type, text, range, etc.).
SNMP is an integral part of the OnAir 3000 implementation. Some informa-
tion, such as DSP temperature are accessible via SNMP only. It is therefor
mandatory to have at least one simple SNMP manager installed in every
system. Many different SNMP manager softwares are available. If none is
present already, an MG-Soft MIB Browser can be provided.
An SNMP.ini file must be available in the OA3000 folder of every
sub system (core, desk, channel screens, etc.) for SNMP operation. Renaming
the template file is sufficient.
If traps are required, the IP address of the SNMP manager (MIB browser) must
be defined in the SNMP.ini file. The desired traps must be commented
out in the SNMP.xml files located in the SNMP folder of every subsystem,
they must be configured individually.