Remote Configuration Tool - Studer OnAir 3000 Operating Instructions Manual

Hide thumbs Also See for OnAir 3000:
Table of Contents

Advertisement

5.13.4

Remote Configuration Tool

Installation
Nice to know:
Document generated: 10.10.14
The (Remote) Configuration Tool is very similar to the Configuration Tool
that can be started from the Remote Console's Admin - Config page. The
only difference is that it allows selection of the console to be configured – so
it is, in fact, useful only in case of a larger networked system.
Important for Windows Vista and Windows 7 PCs: Make sure that you have
write access to the selected location.
• Locate the folder
DVD shipped with your console. Navigate to the
Release Configuration Tool
• Copy the complete folder to a location of your choice on your computer.
• Open the folder you have copied before and make a copy of the
tainer_template.ini
• Edit the
container.ini
- Select a system ID that is not used by another system (you can use the
System Viewer for information), such as
- Give the system a name that makes sense, such as
.
"Admin"
- In the container ID list there already exists an entry 'Standalone Con-
figGUI' that may be selected – so enter
- Give the container a name, such as
It makes sense to use no more than 8 characters due to visualization
aspects.
- If your console(s) is/are working with multicasts in your network,
uncomment one or several of the
(i.e., delete the '
multicast address(es) that your IT administrator should be able to give
you.
- When using multicasts, uncomment the
and enter a value of 10 or higher, depending on the number of routers
through which the multicast has to travel.
- If your computer has more than one network adapter, the MAC address
must be uncommented and specified. You will find the MAC address
under your computer's network settings, such as
in our example.
4F-13-BD
- Alternatively, or if multiple networks are bound to a network adapter,
the base IP address of the network (NetworkAddress) can be specified
instead of the MAC address.
• Save and close the
ration Tool.exe
the tool.
Installation is complete now.
It is possible to configure different consoles being not part of the same mul-
ticast group from a single computer. Just enter all required multicast groups
here; this will allow the configuration tool accessing the consoles, but the
consoles will not 'see' each other although they are within the same network.
The Config Tool
container.ini
SW V6.0
OnAir 3000 Digital Mixing Console
for your console type on the Product
x_SW_Vx.x.x.xx
folder.
file; rename the copy to
file:
containername = "CnfgTool"
# MulticastGroup = ...
' hash mark and the following blank), and enter the
#
f ile. Generate a shortcut to
container.ini
and move it to your desktop for a convenient start of
file used for this example looks as follows:
Win2K_Compilations/
.
container.ini
.
systemid = 80
systemname =
.
containerid = 20
MulticastTimeToLive
MAC = 00-1B-21-
Configu-
Operation 5-165
con-
.
lines
line