Error Code
Error Type Error Text / Comment
Warning
7000
Warning
7002
Warning
7004
Warning
7111
Warning
7200
Warning
7201
Warning
7300
Warning
7301
Warning
7302
Warning
7303
Warning
7400
Warning
7500
Warning
7501
Warning
7502
Warning
7503
Info
7504
5.12.4.2

Core Driver

5-142 Operation
CF CARD, Cannot read card. Unidentified Format!
SYSTEM, Extension ‚UserGUI.ext' could not load User Buttons. Reason: ‹Did not find XML-File or XDR-
File: xml\ GUI_UserButtons.xml'.
SYSTEM, 'UILogic.xml' has an incompatible XDR file. Default settings assumed.
The User Warning appears during power-up if, in case of an optional XML, file the XML and XDR file are
incompatible, e.g. the XDR file of a former software release.
Note: The UILogic.xml file is the only optional xml file.
SYSTEM, Connection to CORE 'System71' lost.
The Routing Snapshots of that CORE can no longer be recalled remotely.
Appears if the CORE loses the network connection to another CORE on which Partial Output Routing
snapshots are configured.
SYSTEM, Number of ‚Logical Inputs' has been truncated to ‚255'
Appears if a number of a certain parameter such as LogicalInputs is configured in the config.xml file that
exceeds the number specified for that parameter (255 in this case).
SYSTEM, CustomLogics are not supported on this system. Enable CustomLogics by increasing system
memory to 512MByte.
Appears, if an OA2500 starts up with some CustomLogics configured and an installed system memory of
254MByte.
SYSTEM, The console set-up cannot be changed, since there is at least one channel on-air. Please make
sure no channel is on-air and try again.
Appears when trying to switch to another console set-up, while a LogicalInput is on-master (FInputStatus ->
ChannelOnMaster).
SYSTEM, The console set-up cannot be changed, since there is at least one remote channel (I/O sharing)
on-air. Please make sure no channel is on-air on a remote system and try again.
Appears when trying to switch to another console set-up while a NetLogicalInput of another system is con-
suming a LogicalInput and is on-master (FInputStatus->ChannelOnMasterNet).
SYSTEM, Please restart core and desk(s) to complete the set-up change.
Appears when switch to another console set-up.
SYSTEM, Please restart the ‚Desk' to complete the set-up change.
Appears when a container is found that (still) has an different setup as the core.
SYSTEM, Product.ini is missing.
Appears after power-up if the file Product.ini is missing
SYSTEM, No Inputs specified in VoiceMix Group Configuration. Configuration ignored.
Using default configuration.
Appears after power-up, if none of the specified VoiceMix Groups has Inputs.
The system uses the default configuration.
SYSTEM, More than '32' Inputs specified in VoiceMix Group Configuration.
Number of Inputs limited to '32'.
Appears after power-up, if the total of inputs of all VoiceMix Groups exceeds 24/32.
The system limits the number of inputs to 24/32 by removing inputs and VoiceMix Groups, if required, from
the configuration.
SYSTEM, Wrong number of Inputs specified for VoiceMix Group '1'. Even number required.
VoiceMix Group '1' has now '12' Inputs.
Appears after power-up, if an odd number of inputs (≠ 1) was specified.
The system corrects the number of inputs to the next lower even number.
SYSTEM, Only a single Input specified for VoiceMix Group '2'. Higher even number required.
VoiceMix Group '2' is ignored.
Appears after power-up, if only a single input was specified.
The system ignores this VoiceMix Group.
SYSTEM, VoiceMix Group Configuration not possible for 'OnAir1500'. Configuration ignored.
Using default configuration.
Appears after power-up, if a VoiceMix Group Configuration is specified for an OnAir1500/2500 console.