OnAir Digital Mixing Consoles
* Codec Return Activation
Joker Function Name
OnAir 1500/2500:
External Router Destination
External CMS Fader
CLEAR Sources
6-18  Configuration
tion Tool provides a list of all net patch inputs on the system of that net
source that are consuming an N–X send from the local system.
Specifies the way in which the return line is connected to the patch output
when the (net) logical input is assigned to a fader. Available selections: Con-
nect Never, Connect If Not In Use, Connect Always.
*
For details on codec management refer to
Basically, all corresponding keys in the fader strip have the same function
throughout the whole console. However, for some functions of certain input
sources this doesn't make sense (such as talkback to a CD player). For this
reason, one exception from this rule may be configured that will then be
source-related, i.e., linked to a particular source, and that will also be con-
sidered once this source should be re-routed to a different channel strip. This
function key is called the 'Joker' key.
Currently, the following functions may be selected for the Joker key: TALK 
(talkback function), LOC/RDY (locate/ready function), PFL/TALK (acti-
vates PFL and talkback simultaneously), PFL/LOC (for pre-listening e.g.
to a CD player parked at a cue point; when releasing the key, the player
automatically re-locates to the same cue point), TALK/READY  (talkback
function with additional ready indication controlled by a GPInput), USR1/2
(user keys) or blank (no function).
Joker key not supported by the default configuration.
With SW V2.1 and later, this parameter is used to assign a destination ID of
an external router output to the logical input; this is used for importing and
displaying labels from the VSM router control system as well as for control-
ling the router.
Selection: - (none) or 0-65535. The default assignment is 1:1, i.e. logical
input 1 corresponds to destination ID 1.
In addition, a Facility ID must be entered in the UserGUI - Settings con-
figuration page (refer to
settings in the ProBel.xml and probel_contr_ext.ini files.
With SW V2.1 and later, the console can communicate commands and status
messages with the Studer Call Management System (CMS) via TCP/IP.
Selection: - (none) or 1-16.
In addition, a Facility ID must be entered in the UserGUI - Settings con-
figuration page (refer to
settings in the cms_contr_ext.ini file.
The top left CLEAR Sources field is colored brighter than the others; it can
be used to clear all configured sources. If it is touched, clearing the sources
has to be confirmed in the following dialog box:
In case that all configured sources should have been cleared inadvertently,
and the current configuration has not been saved yet, they can be restored
step by step when touching the Undo button, as also mentioned in