5.12.4.6

Desk / User GUi / Configuration Tool

Error Code
Error Type Error Text / Comment
Warning
4100
Warning
4101
Warning
4102
Warning
4104
Warning
4105
Warning
4106
Warning
4107
Warning
4108
Warning
4109
Warning
4110
Info
4111
Warning
4112
Warning
4113
Warning
4114
Warning
4200
Warning
4201
Warning
4202
Warning
4203
Warning
4204
Warning
4205
Warning
4206
Warning
4211
Warning
4212
Warning
4214
Document generated: 10.10.14
DESK, No communication with Fader module at Port 43 on Container100.
DESK, File ‚fader3.hex' not found. Firmware download to Fader module at Port 43 on Container100 failed.
DESK, Fader calibration failed, one or more fader uncalibrated on Fader module at Port 43 on Con-
tainer100.
Appears as a result of the fader calibration operation if at least one fader is not within the calibration win-
dow.
DESK, Missing Fader module at Port 12 on Container100.
DESK, Wrong module type at Port 12 on Container100. A Fader module is expected instead of a Rotary
module.
DESK, One or more fader uncalibrated on Fader module at Port 43 on Container100.
Appears after startup or after module connection if a fader module reports uncalibrated faders by the well-
ness status message.
DESK, Could not open port COMX.
Appears during init phase if the specified COM port cannot be opened.
DESK, Main Power Supply fail.
DESK, Redundant Power Supply fail.
DESK, Could not find folder 'Firmware'.
DESK, Module table was changed. Desk 'Container100' must be restarted to take effect of the change.
Appears after Save Config, if First strip number of a module has changed.
DESK, Could not save file on 'Container100': 'Desk_ModuleTable.xml'.
Appears after Save Config, if file could not be saved.
DESK, Error in Module table on 'Container100'. Strips are overlapping or out of configured range. Adjust
'First strip number' parameter.
Appears after Save Config, if strips are overlapping or out of configured range.
DESK, Main meter limit reached. Main meter 1 on OA1K5CentralFader6 module at Port 2 on Container100
not active.
Appears after startup if too many Main Meters are configured in the desk patterns of the configured mod-
ules.
CONFIG, AutoConfig not completed! No input modules detected. No Initial Snapshot created.
CONFIG, AutoConfig not completed! No output modules detected. No Initial Snapshot created.
CONFIG, AutoConfig cannot complete to map all input signals to LogicalInputs. Increase the number of
LogicalInputs and re-run auto configuration.
CONFIG, AutoConfig cannot complete to map all output signals to LogicalOutputs. Increase the number of
LogicalOutputs and re-run AutoConfig.
CONFIG, AutoConfig detected unknown IO-Card in Slot 7.
CONFIG, AutoConfig cannot complete to map all GPInputs to GPInputFunctions. Increase the number of
GPInputFunctions and re-run auto configuration.
CONFIG, AutoConfig cannot complete to map all GPOutputs to GPOutputFunctions. Increase the number
of GPOutputFunctions and re-run auto configuration.
CONFIG, Alias is already in use! Alias will not be changed.
The Warning appears if an Alias is defined a second time in the ConfigGUI.
DESK, The Alias 'Input 1" appears twice in the range of LogicalInputs of Desk 'Primary Desk'.
The warning appears during power-up or when the Desk Resource Definition is changed so that two Logi-
cal Inputs in the range of that desk have the same alias, or if such an alias conflict happens during power-
up of a desk container.
Appears only if at least one desk is running, since the DRD is used for the double alias check.
CONFIG, Not enough DSP channels. The format of input "DVD 5.1" cannot be changed.
Appears when trying to change the format of a logical input from mono or stereo to 5.1 in the Config GUI
but not enough DSP channels are available.