Studer OnAir 3000 Operating Instructions Manual page 272

Hide thumbs Also See for OnAir 3000:
Table of Contents

Advertisement

PPM DIN
Nordic Analog
Meter Integration Time
VU Meter Lead
Document generated: 10.10.14
boost for the S bargraph can be selected as well. This is indicated either by
L and R, or by M and S (or M/S+20) below the bargraph meters. Additional
red clipping indicators are provided above the bargraphs.
The Digital FS Meter always displays the current level with reference to full
scale modulation (0 dB
FS
point from the green to the red part of the bargraph meters. Additional red
clipping indicators are provided above the bargraphs.
Nordic Digital
VU Standard
The meter integration time, i.e. the rise time, can be set here in four steps
(NONE, FAST, IEC Type I, and IEC Type II) corresponding to 0, 1, 5, and
10 ms (milliseconds). The default setting is IEC Type II. If VU Standard 
or British Standard is selected, the integration time is fixed, and the Meter
Integration Time field is grayed out.
The default VU meter lead is 4 dB; it can be adjusted in steps of 2 dB within
a range of 0 to 10 dB.
SW V6.0
OnAir Digital Mixing Consoles
). The current headroom setting defines the transition
British Standard
Digital FS Meter
Configuration  6-31