OnAir 3000 Digital Mixing Console
5.13.3

Remote Console Application

Installation
5-160 Operation
Important for Windows Vista and Windows 7 PCs: Make sure that you have
write access to the selected location.
• Locate the
x_SW_Vx.x.x.xx
DVD shipped with your console. Navigate to the
Release RemoteConsole
• Copy the complete folder to a location of your choice on your computer
(perhaps to the desktop).
• Open the folder you have copied before and make a copy of the
tainer_template.ini
• Edit the
container.ini
on the following pages):
- First, set the
systemid
to 111 in our example). Please note that on both sides of the '=' sign a
blank is mandatory. The system ID is defined as the 3 least-significant
digits of the Nano SCore's serial number you are connecting to. In
case these 3 digits should be greater than 255, it is equal to [the last 3
digits modulo 255]. Calculate as follows: Subtract 255 from the last 3
digits as many times as needed for a remainder between 0 and 255; the
remainder is the result.
Example: If the last 3 digits are 621, enter 111 for it (621 – 255 = 366,
and 366 – 255 = 111). The system ID can also be found out using the
System Viewer application, refer to
- Set
systemname
in our example).
- Set the container ID – you may use, e.g. the
ID that equals 150. The 'container' in this case is the PC that
allel)
runs the Remote Console application.
- Give the container a name, such as
.
sole"
- If your console(s) is/are working with multicasts in your network,
uncomment one or several of the
(i.e., delete the '
multicast address(es) that your IT administrator should be able to give
you.
- When using multicasts, uncomment the
and enter a value of 10 or higher, depending on the number of routers
through which the multicast has to travel.
- If your computer has more than one network adapter, the MAC address
must be uncommented and specified. You will find the MAC address
under your computer's network settings, such as
in our example.
4F-13-BD
- Alternatively, or if multiple networks are bound to a network adapter,
the base IP address of the network (NetworkAddress) can be specified
instead of the MAC address.
• Save and close the
and move it to your desktop for a convenient start of the
Console.exe
tool.
Installation is complete now.
The Remote Console
on the following pages.
SW V6.0
folder for your console type on the Product
folder.
file; rename the copy to
file (an example of a container.ini file is located
parameter to the System ID of your core (i.e.,
chapter
to the System Name of your core (i.e.,
containername = "Remote Con-
# MulticastGroup = ...
' hash mark and the following blank), and enter the
#
f ile. Generate a shortcut to
container.ini
file used for this example is printed
container.ini
Win2K_Compilations/
con-
.
container.ini
5.13.2.
"P1K5_111"
Secondary DESK (par-
lines
MulticastTimeToLive
MAC = 00-1B-21-
Remote-
Document generated: 10.10.14
line