Pro-Bel Controller Extension; Cms Controller Extension; I/O Sharing - Studer OnAir 3000 Operating Instructions Manual

Hide thumbs Also See for OnAir 3000:
Table of Contents

Advertisement

OnAir 3000 Digital Mixing Console
5.12.4.12

Pro-Bel Controller Extension

Error Code
Error Type Error Text / Comment
Warning
8200
Warning
8201
Warning
8202
5.12.4.13

CMS Controller Extension

Error Code
Error Type Error Text / Comment
Warning
8301
5.12.4.14

i/O Sharing

Error Code
Error Type Error Text / Comment
Warning
8500
Warning
8501
Warning
8503
Warning
8504
Warning
8506
Warning
8507
Warning
8508
Warning
8509
5-154 Operation
PROBEL Controller, Could not open port COMX.
Appears during init phase if the specified COM port cannot be opened. This can happen if the CAB exten-
sion is running within the same container as the ProBel controller extension.
PROBEL Controller, "Master Channel Base" conflicts with logical input or patch input numbers.
Appears during init phase if the tree parameter "Master Channel Base" ss maller than the input number of
the last logical output. Set "Master Channel Base" to an appropriate value.
PROBEL Controller, Connection lost to External Router Control System (RCS)
If all redundant systems of a session/facility does not answer anymore or the connection of the session is
lost.
CMS Controller, Connection lost to external Call Management System (CMS)
If the CMS Client of a session/facility does not answer anymore or the connection of the session is lost.
IOSHARING, Did not find XML-file: xml\IoSharing.xml
Appears during power up if IoSharing.xml could not be found.
IOSHARING, Could not reset physical connection, since it is still in use!
The HD LINK Out parameter of an HD LINK Input may only be changed if the parameter "UsageCounter"
of the HD LINK Input is = 0. Otherwise this warning will appear.
IOSHARING, I/O Sharing not enabled on system ‚P422'. Missing dongle or license key. IO-Sharing will not
work properly.
Appears if the specified system (either the local system which is the consumer or the producer) has no
dongle on the audio clock card and no key is defined to enable I/O Sharing.
IOSHARING, Audio connection could not be established, since there are too few physical connections
available. No audio on 'left' channel of 'Logical Input' 'Label' !
Appears as soon as a logical connection should be established, but no free physical connection is avail-
able.
IOSHARING, Could not modify NetInput, since it is still in use by ‚Ext MonSource16' on system ‚P422'.
Appears during defining, un-defining or changing a Source of a NetInput if there is at least one NetCon-
sumer registered. The User warning indicates the last registered NetConsumer.
IOSHARING, Connection to producer CORE 'System71' lost.
Appears if the CORE loses the network connection to another CORE of a remote system, to which logical
connections are allocated (neighbouring systems only).
IOSHARING, Conflict while system ‚P422' is re-establishing a physical connection. The 'left channel' of the
local output ‚LogOut44' will be disconnected and re-used for the physical connection to system ‚P422'!
Appears on the producer system during start-up of a consumer system if the I/O sharing extension tries to
initialise a producer's HD LINK Output that is already in use locally (LogicalOutput, FixedOutput,...).
IOSHARING, Conflict while re-establishing a physical connection to HD Link '35'. Physical output 'Ext 4,
Slot 3, Line Out, Ch.33' of system'P422' is already used by a physical connection to system ‚P321'. The
physical connection could not be established!
Appears during start-up of a consumer system if the I/O sharing extension tries to initialise a producer's HD
LINK Output that is already in use by a physical connection to another consumer system.
SW V6.0
Document generated: 10.10.14