6.5.35
user (user Management)
6.5.35.1
Admin
FaderScaleMode
Switchover Behaviour:
Motor Fader Module • Physical fader position below the 0 dB marker: The fader knob moves up
Non-Motor Fader Module
Document generated: 10.10.14
The system administrator ('Admin', user no. 1) automatically has access to
all features of the console and its configuration; for him, only the Admin
policy (no. 1) is valid. No other policy may be assigned to him; however, the
Admin policy may be assigned to other users, if required.
The administrator's user name and his password may be changed using the
pop-up keyboard; the factory default settings are Admin for his user name,
and admin for his password. Please note that the password is case-sensitive
– this is important for correct log-in.
Since SW V3.2 an additional setting can be made here: Either the standard
+10 dB on Fader Top or the new 0 dB on Fader Top. This can be set
individually for every user.
Depending on the used fader modules and the physical fader positions, dif-
ferent behaviours have to be considered; however, the functionality has been
designed in such a way that the switchover either causes no level jump at all
or that an unavoidable level jump is kept as small as possible. During every-
day operation, the function is switched over only when a different user logs
in and the faders are down.
When switching from 0 dB on Fader Top to +10 dB on Fader Top: No
level jumps occur in any case.
When switching from +10 dB on Fader Top (standard) to 0 dB on Fader
Top:
by 10 dB, no audio level jump occurs.
• Physical fader position above the 0 dB marker: The fader motor is turned
off; upon touching the fader knob, the audio level jumps down by 10 dB;
this cannot be avoided, except if taking care that the faders are below the
0 dB marker on switchover.
The fader goes into take-over mode, regardless of its physical position; when
moving the fader button until the physical and the electrical fader positions
match again, no level jump occurs in any case.
SW V6.0
OnAir Digital Mixing Consoles
Configuration 6-115