GPOutput
A GPOutput consists of a control output on a D21m GPIO or Ethersound card
and the appropriate output logic.
Level
FixedLabel is defined by the system and remains 'read only'. It contains a
text specifying the location of the physical ouput, such as 'Int, Slot 3, Out 2'.
Label is initialized by the software as 'GPOutput N' by default. It can be
changed by the user.
Source allows defining a 'Level Producer' since GPOutputs are (net-) con-
sumers. The following producers are allowed:
• Local or remote GPInput
• Local or remote GPOutput function
• Local or remote Custom Logic
For further details on the parameters and the 'Level' term, refer to
6.5.29.2.1.
The number of GPOutputs is configured in the D21m.xml file. It has to
match the number of actually available physical GP outputs in the D21m
system.
SW V6.0
OnAir Digital Mixing Consoles
FixedLabel
Label
Time
Physical
Polarity
Input
TriggeredEdge
Activate
Source
chapter
Configuration  6-75