Studer OnAir 3000 Operating Instructions Manual page 324

Hide thumbs Also See for OnAir 3000:
Table of Contents

Advertisement

Document generated: 10.10.14
Example 1, Inactive
If the output is deactivated, the output signal remains constant, regardless of
the 'Level' attribute.
Level
Output
Pin
Pin Attributes
Setting
Off
Activate
--
Time
positive
Polarity
both
Triggered Edge
Example 2, Normal Output Mode
To make the output follow the 'Level' attribute, the 'Active' attribute must
be set, and the 'Triggered Edge' attribute must be set to 'both'. The 'Time'
attribute is ignored in such a case.
Level
Output
Pin
Pin Attributes
Setting
On
Activate
--
Time
positive
Polarity
both
Triggered Edge
Example 3, Latching Mode:
To get the level latched at the output pin, the 'Triggered Edge' attribute must
be set to either 'rising' or 'falling', the 'Time' attribute must be 0 ms.
Level
Output
Pin
Pin Attributes
Setting
On
Activate
0 ms
Time
positive
Polarity
rising
Triggered Edge
Level
Output
Pin
Pin Attributes
Setting
On
Activate
0 ms
Time
positive
Polarity
falling
Triggered Edge
SW V6.0
OnAir Digital Mixing Consoles
Level
Output
Pin
Pin Attributes
Activate
Time
Polarity
Triggered Edge
Level
Output
Pin
Pin Attributes
Activate
Time
Polarity
Triggered Edge
Level
Output
Pin
Pin Attributes
Activate
Time
Polarity
Triggered Edge
Level
Output
Pin
Pin Attributes
Activate
Time
Polarity
Triggered Edge
Configuration  6-83
Setting
Off
--
negative
both
Setting
On
--
negative
both
Setting
On
0 ms
negative
rising
Setting
On
0 ms
negative
falling