Header - IBM WebSphere XS40 Command Reference Manual

Datapower xml security gateway
Table of Contents

Advertisement

threshold
burst-limit
control-procedure
Guidelines
You can add multiple filters to a count monitor.
After completing the configuration of a count monitor, activate the monitor by
assigning it to a DataPower service.
Use the no filter command to remove a filter from a count monitor.
Related Commands
measure, message-type, show Message Count-filters
Examples
v Defines the LogSquelch Message Count monitor. If the Extranet message class

header

Specifies the HTTP header to read to determine the client IP address.
Syntax
header name
Parameters
name
Related Commands
source
Examples
v Designates the X-Client-IP HTTP Header to read to determine the client IP
414
Command Reference
Specifies the threshold value. Exceeding this value triggers the specified
the control procedure.
Specifies an acceptable traffic burst. The value should be approximately
twice the threshold value.
Specifies the name of a control procedure that was created with the
monitor-action command. This control procedure is triggered when the
threshold value is exceeded.
exceeds 50 client requests (the default counter) per second, implement the
Squelch control procedure which logs an error and imposes a 2.5 second
blackout on the Extranet message class.
# monitor-count LogSquelch
Message count monitor Configuration mode
# message-type Extranet
# filter Filter1 1000 50 100 Squelch
#
Specifies the name of the HTTP header to read.
address.
# monitor-count LogSquelch
Message count monitor Configuration mode
# header X-Client-IP