Interface Description - X2 - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

4.10.1

Interface description - X2

The motor power interface located on the Wiring Module is available only for the G115D wall-
mounted converter. For a G115D converter with SIMOGEAR geared motor, the wiring
between the converter and the motor is completed when delivered.
Connector variant
Q8/0 connector
X2 - motor power,
8-pin, female
Glanded variant
X2 - motor power terminals
Further information
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Pin
Signal
1
U
2
-
3
W
4
EM-/EM2
5
T+
6
EM+/EM1
7
V
8
T-
9
PE
Glanded installation kit (Page 32)
Cables and connectors (Page 62)
Description
Phase U
Not connected
Phase W
EM brake negative (180 V DC) / EM brake 2 (400 V AC)
Motor temperature sensor positive
EM brake positive (180 V DC) / EM brake 1 (400 V AC)
Phase V
Motor temperature sensor negative
Protective earth
Signal
Description
U
Phase U
V
Phase V
W
Phase W
EM+
EM brake positive (180 V DC)
EM-
EM brake negative (180 V DC)
EM1
EM brake 1 (400 V AC)
EM2
EM brake 2 (400 V AC)
T+
Motor temperature sensor positive
T-
Motor temperature sensor negative
Protective earth
Screw tightening torque:
U/V/W: 1.0 Nm/8.9 lbf.in;
: 2.2 Nm/19.5 lbf.in
Cable gland size: M25 * 1.5
Wiring