Table 6- 2
Number
p1030[0...n]
p1037[0...n]
p1038[0...n]
p1043[0...n]
p1044[0...n]
Further information
For more information about the motorized potentiometer, refer to function diagram 3020 in
the List Manual.
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Advanced settings
Name
Motorized potentiometer
configuration
Motorized potentiome-
ter, maximum speed
[rpm]
Motorized potentiome-
ter, minimum speed
[rpm]
BI: Motorized potentiom-
eter, accept setting value
CI: Motorized potentiom-
eter, setting value
Factory setting
Configuration for the motorized potentiometer
Factory setting: 00110 bin
.00
Storage active
= 0: After the motor has been switched on, the setpoint =
p1040
= 1: After the motor has switched off, the converter saves
the setpoint.
After the motor has switched on, the setpoint = the stored value.
.01
Automatic mode, ramp-function generator active (1-signal
via BI: p1041)
= 0: Ramp-up/ramp-down time = 0
= 1: With ramp-function generator
In manual mode (p1041 = 0), the ramp-function generator
is always active.
.02
Initial rounding active
1: With initial rounding. Using the initial rounding function
it is possible to enter very small setpoint changes.
.03
Storage in NVRAM active
1: If bit 00 = 1, the setpoint is retained during a power
failure.
.04
Ramp-function generator always active
1: The converter also calculates the ramp-function genera-
tor when the motor is switched off.
The converter limits the motorized potentiometer output
to p1037.
Factory setting: 0 rpm
After quick commissioning, the converter sets the parame-
ter to the appropriate value.
The converter limits the motorized potentiometer output
to p1038.
Factory setting: 0 rpm
After quick commissioning, the converter sets the parame-
ter to the appropriate value.
Signal source for accepting the setting value. The motor-
ized potentiometer accepts the setting value p1044 on
signal change p1043 = 0 → 1.
Factory setting: 0
Signal source for the setting value
Factory setting: 0
Advanced commissioning
6.15 Setpoints
235