Procedure with Startdrive when the safety functions are enabled
1. Save the project.
2. Select the
3. Connect Startdrive online with the drive.
4. Press the
5. Enter the password for the safety functions.
If the password is the factory default, you are prompted to change the password.
If you try to set a password that is not permissible, the old password will not be changed.
6. Press the
7. Confirm the prompt for saving your settings (copy RAM to ROM).
8. Disconnect the online connection.
9. Switch off the converter power supply.
10.Wait until all LEDs on the converter go dark (no voltage condition).
11.Switch on the converter power supply again.
You have transferred the settings from the PG/PC to the converter with Startdrive and have
activated the safety functions.
Transferring using SINAMICS G120 Smart Access
You can use the SINAMICS G120 Smart Access to transfer settings. For more information on
the transferring process, see Section "Backup and restore" in the SINAMICS G120 Smart
Access Operating Instructions.
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
button to transfer settings from the PG/PC to the converter.
button to start the safety commissioning.
button to end the safety commissioning.
Overview of the manuals (Page 542)
Data backup and series commissioning
7.2 Transferring settings using a PG/PC
313