Mounting
3.1 Mounting the G115D Motor Mounted drive
Mounting positions
The SINAMICS G115D Motor Mounted drive supports mounting positions M1 to M6. You
mount the drive based on the desired mounting configuration for the geared motor.
The figure below shows the SINAMICS G115D converter with SIMOGEAR geared motor in
mounting positions M1 to M6.
Mounting dimensions
All dimensions are specified in millimeters (inches).
Converter
frame size
FSA
FSB
The glanded variant of the converter provides no cable gland when delivered. The dimension data
1)
of glanded variant applies to the drive installed with the optional glanded installation kit.
36
Motor
Length
Length
frame size
L
l1
71
240
53.5 (2.11)
(9.4)
80
25 (0.98)
90
0.5 (0.02)
90
285
27 (1.06)
(11.2)
100
5 (0.2)
112
-3 (-0.12)
Width
Height
W
SH
146
177.5 (7.0)
(5.7)
196 (7.7)
201 (7.9)
180
206 (8.1)
(7.1)
217.5 (8.6)
228.5 (9.0)
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Additional width
1)
C
Connector variant: +47.5
(1.87)
Glanded variant: +30 (1.18)
Converter with 24 V PSU: +60
)
(2.36
SINAMICS G115D distributed drive