Technical Data Of Braking Resistors - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Standby currents
G115D motor-mounted converter
Frame size
Rated power
FSA
0.37 kW to 1.5 kW
FSB
2.2 kW to 4 kW
G115D motor-mounted converter
Frame size
Rated power
FSA
0.37 kW to 1.5 kW
FSB
2.2 kW to 4 kW
10.1.4

Technical data of braking resistors

Technical data of integrated braking resistor
G115D motor-mounted converter
Frame size
FSA
FSB
Peak power at 10% cycle time of a 120s cycle.
1)
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
10.1 Technical data of the G115D converter with SIMOGEAR geared motor
Standby current (mA)
Mains power supply without optional 24 V DC power supply
380 V, 50 Hz
380 V, 60 Hz
32
39
69
83
Standby current (mA)
Mains power supply with optional 24 V DC power supply
380 V, 50 Hz
380 V, 60 Hz
64
71
101
115
Rated power
Resistance
0.37 kW to 1.5 kW
350 Ω
2.2 kW to 4 kW
175 Ω
400 V, 50 Hz
400 V, 60 Hz
34
41
73
87
400 V, 50 Hz
400 V, 60 Hz
62
69
101
115
Integrated braking resistor
Continuous braking power
10 W
10 W
Technical data
480 V, 50 Hz
480 V, 60 Hz
41
49
87
104
480 V, 50 Hz
480 V, 60 Hz
59
67
105
122
Peak braking power
100 W
100 W
363
1)

Advertisement

Table of Contents
loading

Table of Contents