Advanced commissioning
6.6 Drive control via Ethernet/IP
No.
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
156
Type
Service Name
REAL
get, set PID Filter Time Constant p2265 technology controller actual value
REAL
get, set PID D Gain
REAL
get, set PID P Gain
REAL
get, set PID I Gain
REAL
get, set PID Up Limit
REAL
get, set PID Down Limit
REAL
get
Speed setpoint
REAL
get
Output Frequency
REAL
get
Output Voltage
REAL
get
DC Link Voltage
REAL
get
Actual Current
REAL
get
Actual Torque
REAL
get
Output power
REAL
get
Motor Temperature
REAL
get
Power Unit Temperature
REAL
get
Energy kWh
UINT8
get
CDS Eff (Local Mode)
WORD
get
Status Word 2
WORD
get
Control Word 1
REAL
get
Motor Speed (Encoder)
UINT32
get
Digital Inputs
UINT32
get
Digital Outputs
REAL
get
Analog Input 1
REAL
get
Analog Input 2
REAL
get
Analog Output 1
REAL
get
Analog Output 2
UINT16
get
Fault Code 1
UINT16
get
Fault Code 2
UINT16
get
Fault Code 3
UINT16
get
Fault Code 4
UINT16
get
Fault Code 5
UINT16
get
Fault Code 6
UINT16
get
Fault Code 7
UINT16
get
Fault Code 8
REAL
get
Pulse Frequency
UINT16
get
Alarm Code 1
UINT16
get
Alarm Code 2
UINT16
get
Alarm Code 3
UINT16
get
Alarm Code 4
REAL
get
PID setpoint Output
REAL
get
PID Feedback
REAL
get
PID Output
Value/explanation
filter time constant
p2274 technology controller differentiation
time constant
p2280 technology controller proportional gain
p2285 technology controller integral time
p2291 technology controller maximum limiting
p2292 technology controller minimum limiting
r0020 speed setpoint
r0024 output frequency
r0025 output voltage
r0026[0] DC link voltage
r0027 current actual value
r0031 torque actual value
r0032 actual active power value
r0035[0] motor temperature
r0037[0] power unit temperature
r0039 energy display
r0050 active command data set
r0053 status word 2
r0054 control word 1
r0061 speed actual value
r0722 digital inputs status
r0747 digital outputs status
r0752[0] analog input 1
r0752[1] analog input 2
r0774[0] analog output 1
r0774[1] analog output 2
r0947[0] fault number 1
r0947[1] fault number 2
r0947[2] fault number 3
r0947[3] fault number 4
r0947[4] fault number 5
r0947[5] fault number 6
r0947[6] fault number 7
r0947[7] fault number 8
r1801 pulse frequency
r2110[0] alarm number 1
r2110[1] alarm number 2
r2110[2] alarm number 3
r2110[3] alarm number 4
r2260 technology controller setpoint after the
ramp-function generator
r2266 technology controller actual value after the
filter
r2294 technology controller output signal
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
SINAMICS G115D distributed drive