Electromechanical Potentiometer - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Advanced commissioning
6.15 Setpoints
6.15.3

Electromechanical potentiometer

The converter has two electromechanical potentiometers.
The potentiometers are hardwired with the internal analog inputs 0 and 1.
For more information on using a tool to adjust the two electromechanical potentiometers,
refer to the replacing procedure in Section "Replacing the Electronic Module (Page 344)".
Setting the potentiometer as setpoint source
Parameter
p1070[0] = 755[0]
p1070[1] = 755[1]
p1075[0] = 755[0]
p1075[1] = 755[1]
232
Description
Main setpoint
Interconnect the main setpoint with the internal analog inputs 0 and 1.
Additional setpoint
Interconnect the additional setpoint with the internal analog inputs 0 and 1.
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
SINAMICS G115D distributed drive