Siemens SINAMICS G115D Operating Instructions Manual page 145

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

No.
04 hex No array (access with a subindex to non-indexed parameters)
05 hex
06 hex
07 hex Descriptive element cannot be changed (change request to a descriptive element error
0B hex No master control (change request but with no master control, see also p0927.)
0C hex Keyword missing
11 hex Request cannot be executed due to the operating state (access is not possible for tempo-
14 hex Inadmissible value (change request with a value that is within the limits but which is illegal
65 hex Parameter number is currently deactivated (depending on the mode of the converter)
66 hex Channel width is insufficient (communication channel is too small for response)
68 hex Illegal parameter value (parameter can only assume certain values)
6A hex Request not included / task is not supported (the valid request identifications can be found
6B hex No change access for a controller that is enabled. (The operating state of the converter
86 hex Write access only for commissioning (p0010 = 15) (operating state of the converter pre-
87 hex Know-how protection active, access locked
C8 hex Change request below the currently valid limit (change request to a value that lies within
C9 hex Change request above the currently valid limit (example: a parameter value is too large
CC hex Change request not permitted (change is not permitted as the access code is not available)
PNU (parameter number) and page index
The parameter number is located in value PNU in the 1st word of the parameter channel (PKE).
The page index is located in the 2nd word of the parameter channel (IND bit 7 ... 0).
Parameter number
0000 ... 1999
2000 ... 3999
6000 ... 7999
8000 ... 9999
10000 ... 11999
20000 ... 21999
30000 ... 31999
60000 ... 61999
Subindex
For indexed parameters, the parameter index is located in subindex (IND Bit 15 ... 8) as
hexadecimal value.
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Description
Incorrect data type (change request with a value that does not match the data type of the parameter)
Setting not permitted, only resetting (change request with a value not equal to 0 without permission)
value that cannot be changed)
rary reasons that are not specified)
for other permanent reasons, i.e. a parameter with defined individual values)
in table "Request identifications controller → converter")
prevents a parameter change)
vents a parameter change)
the "absolute" limits, but is however below the currently valid lower limit)
for the converter power)
PNU
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
Advanced commissioning
6.5 Drive control via PROFINET
Page index
0 hex
80 hex
90 hex
20 hex
A0 hex
50 hex
F0 hex
74 hex
143