Corrective maintenance
9.3 Replacing the spare parts
9.3.3
Replacing the fan unit
The G115D wall-mounted converter FSB/FSC is integrated with a fan unit.
The average service life of the fan is 40,000 hours. In practice, however, the service life may
deviate from this value. The dusty environment, in particular, can block up the fan. Make sure
that you replace the defective fan in time to ensure the proper operation of the converter
Precondition
• You have switched off the converter power supply before replacing the fan unit.
Procedure
1. Switch off all power supplies (line supply and external 24 V power supply) to the converter.
2. Release the 4 retaining screws on the fan cover.
3. Release the M8 connector on the Electronic Module.
346
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
SINAMICS G115D distributed drive