Siemens SINAMICS G115D Operating Instructions Manual page 306

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Advanced commissioning
6.28 Switchover between different settings
Selecting the number of drive data sets
Parameter p0180 defines the number of drive data sets (1 ... 4).
Parameter
p0010 = 0
p0010 = 15
p0180
Copying the drive data sets
Parameter
p0819[0]
p0819[1]
p0819[2] = 1
Parameters
Parameter
p0010
r0051.0...1
p0180
p0819[0...2]
p0820[0...n]
p0821[0...n]
p0826[0...n]
304
Description
Drive commissioning parameter filter
CO/BO: Drive data set DDS effective
Number of Drive data set (DDS)
Copy drive data set DDS
BI: Drive data set DDS selection, bit 0
BI: Drive data set DDS selection, bit 1
Motor changeover, motor number
Description
Drive commissioning: Ready
Drive commissioning: Data sets
Drive data set (DDS) number
Description
Source drive data set
Target drive data set
Starts the copy operation
Setting
Sets the parameter filter to commission a drive.
0: Ready
1: Quick commissioning (factory setting)
15: Data sets
Displays the effective Drive Data Set (DDS).
p0180 = 1, 2, 3 or 4
Factory setting: 1
[0] Source Drive Data Set
[1] Target Drive Data Set
[2] 0→1: Starts the copy operation
Factory setting: 0
Sets the signal source to select DDS, bit 0.
Factory setting: 0
Sets the signal source to select DDS, bit 1.
Factory setting: 0
Sets the freely assignable motor number for
the drive data set changeover.
Factory setting: 0
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002