Parameter
p2111
p3950
p3981
p3985
p7761
p8805
p8806[0...53]
p8807[0...15]
p8808[0...53]
p8809[0...53]
p9400
p9484
For more information about those parameters, see the List Manual.
7.5

Know-how protection

Overview
Know-how protection prevents unauthorized reading of the converter settings.
To protect your converter settings against unauthorized copying, in addition to know-how
protection, you can also activate copy protection.
Precondition
Know-how protection is applicable for the following user interfaces:
• Startdrive PC tool
• Parameter changes via fieldbus
Know-how protection requires a password.
Combination of know-how protection and copy
protection
Know-how protection without copy protection
Know-how protection with basic copy protection
Know-how protection with extended copy protection
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Description
Alarm counter
Service parameter
Acknowledge drive object faults
Master control mode selection
Write protection
Identification and Maintenance 4
Configuration
Identification and Maintenance 1
Identification and Maintenance 2
Identification and Maintenance 3
Identification and Maintenance 4
Safely remove memory card
BICO interconnections search
signal source
Data backup and series commissioning
7.5 Know-how protection
Setting
Number of alarms that have occurred after the
last reset.
For service personnel only.
Setting to acknowledge all active faults of a drive object.
Sets the mode to change over the master control /
LOCAL mode.
Setting for activating/deactivating the write pro-
tection for adjustable parameters.
Sets the configuration for the content of identifi-
cation and maintenance 4 (I&M 4, p8809).
Parameters for the PROFINET data set "Identifica-
tion and Maintenance 1" (I&M 1).
Parameters for the PROFINET data set "Identifica-
tion and Maintenance 2" (I&M 2).
Parameters for the PROFINET data set "Identifica-
tion and Maintenance 3" (I&M 3).
Parameters for the PROFINET data set "Identifica-
tion and Maintenance 4" (I&M 4).
Setting and display when memory card is "re-
moved safely".
Sets the signal source (BO/CO parameter, BICO
coded) to search in the signal sinks.
Is a memory card necessary?
The converter can be operated with or without
memory card.
The converter can only be operat-
ed with a Siemens memory card.
Memory cards (Page 305)