Siemens SINAMICS G115D Operating Instructions Manual page 209

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Parameter
p1113[0...n]
p3384
p3385
p3386
p3387
p3388
p3389
p3390
p3391
p3392
p3393
p3394
p3395
r3396.0...16
p3397
p3398
r3399
For more information about the conveyor control function, refer to the parameter list and
function diagrams 7040 to 7051 in the List Manual.
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
6.9 Conveyor technology control functions (for G115D PROFINET and AS-i variants only)
Description
BI: Setpoint inversion
BI: Stop sensor positive
direction signal source
BI: Stop sensor negative
direction signal source
BI: Stop sensor center
signal source
BI: Low speed sensor
positive direction signal
source
BI: Low speed sensor
negative direction
signal source
BI: Low speed sensor
center signal source
BI: Stop/low speed
sensor bypass signal
source
BI: Stop/low speed
sensor bypass manual
operation signal source
End position shutdown
activation
Conveyor technology
application selection
Stop sensor evaluation
type
Low speed sensor
evaluation type
CO/BO: Conveyor tech-
nology application
status
CI: Rapid traverse set-
point signal source
CI: Low speed setpoint
signal source
CO: Setpoint active
Setting
Signal source for inverting the setpoint.
1 signal: Invert setpoint
The factory setting depends on the converter fieldbus interface.
Sets the signal source of the stop sensor for the positive direction.
Factory setting: 0
Sets the signal source of the stop sensor for the negative direction.
Factory setting: 0
Sets the signal source of the stop sensor for the middle position.
Factory setting: 0
Sets the signal source of the low speed sensor for the positive direction.
Factory setting: 0
Sets the signal source of the low speed sensor for the negative direction.
Factory setting: 0
Sets the signal source of the low speed sensor for the middle position.
Factory setting: 0
Sets the signal source for bypassing the stop and low speed sensors.
1 signal: The stop and low speed sensors are not taken into account.
The factory setting depends on the converter fieldbus interface.
Sets the signal source for bypassing the stop and low speed sensors in
the "manual operation" mode.
Factory setting: 8559.4
= 0: End position shutdown deactivated. Travel can be continued in both
directions.
= 1: End position shutdown activated (factory setting). Travel can only
be continued in the opposite direction.
Selects the conveyor technology application.
Factory setting: 0
= 1: Input signal high level triggered
= 2: Input signal low level triggered (factory setting)
= 3: Input signal 0→1 edge triggered
= 4: Input signal 1→0 edge triggered
See p3394.
Factory setting: 4
Displays the status of the conveyor technology application.
Sets the signal source of the high speed setpoint.
The setpoint for the input is interconnected with the main setpoint
p1070.
Sets the signal source of the low speed setpoint. The connector input
can be interconnected with a fixed setpoint (p1001 and following) or
potentiometer (r0752).
Factory setting: 0
Displays the active setpoint of the conveyor technology application.
Advanced commissioning
207