Current Derating As A Function Of The Line Voltage; Current Derating As A Function Of The Pulse Frequency - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Technical data
10.2 Technical data of the G115D wall-mounted converter
10.2.6.3

Current derating as a function of the line voltage

The converter operates at 100% rated output current at a line voltage from 380 V to 480 V.
The permissible converter output current is reduced linearly when the line voltage is above
480 V.
10.2.6.4

Current derating as a function of the pulse frequency

The permissible converter output current is reduced when the converter is operated at a
pulse frequency above 4 kHz.
The pulse frequency reduces automatically based on the heatsink temperature.
Frame size
Rated power based on HO (kW)
Rated current (A)
≤4 kHz
40 °C
*
50 °C
55 °C
6 kHz
40 °C
50 °C
55 °C
8 kHz
40 °C
50 °C
55 °C
10 kHz
40 °C
50 °C
55 °C
12 kHz
40 °C
50 °C
55 °C
14 kHz
40 °C
50 °C
55 °C
16 kHz
40 °C
50 °C
55 °C
* Factory setting: 4 kHz
378
FSA
0.37
0.55
0.75
1.1
1.3
1.7
2.2
3.1
1.30
1.70
2.20
3.10
0.91
1.19
1.54
2.17
-
1.11
1.45
1.87
2.64
0.77
1.01
1.31
1.84
-
0.91
1.19
1.54
2.17
0.64
0.83
1.08
1.52
-
0.78
1.02
1.32
1.86
0.55
0.71
0.92
1.30
-
0.65
0.85
1,10
1.55
0.46
0.60
0.77
1.09
-
0.59
0.77
0.99
1.40
0.41
0.54
0.69
0.98
-
0.52
0.68
0.88
1.24
0.36
0.48
0.62
0.87
-
FSB
1.5
2.2
3
4.1
5.9
7.7
4.10
5.90
7.70
2.87
4.13
5.39
3.25
4.24
3.49
5.02
6.55
2.44
3.51
4.58
2.76
3.60
2.87
4.13
5.39
2.01
2.89
3.77
2.27
2.96
2.46
3.54
4.62
1.72
2.48
3.23
1.95
2.54
2.05
2.95
3.85
1.44
2.07
2.70
1.62
2.12
1.85
2.66
3.47
1.29
1.86
2.43
1.46
1.91
1.64
2.36
3.08
1.15
1.65
2.16
1.30
1.69
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
FSC
4
5.5
7.5
10.2
13.2
19
10.20
13.20
19.00
7.14
9.24
13.30
5.61
7.26
10.45
8.67
11.22
16.15
6.07
7.85
11.31
4.77
6.17
8.88
7.14
9.24
13.30
5.00
6.47
9.31
3.93
5.08
7.32
6.12
7.92
11.40
4.28
5.54
7.98
3.37
4.36
6.27
5.10
6.60
9.50
3.57
4.62
6.65
2.81
3.63
5.23
4.59
5.94
8.55
3.21
4.16
5.99
2.52
3.27
4.70
4.08
5.28
7.60
2.86
3.70
5.32
2.24
2.90
4.18
SINAMICS G115D distributed drive

Advertisement

Table of Contents
loading

Table of Contents