Cooling; Fastening For Suspended Transport - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

11.3.5

Cooling

NOTICE
Dust deposits prevent heat radiation
Dust deposits prevent heat radiation and cause a high housing temperature.
Keep the gearbox free from dirt, dust, etc.
The gearbox does not normally require additional cooling. The generously dimensioned
housing surface is sufficient for dissipating heat losses where there is free convection. If the
housing temperature exceeds a value of +80 °C, please contact Technical Support.
11.3.6

Fastening for suspended transport

Inadequately fastened gearboxes or geared motors can break loose
Use only the transport eye or eyebolt of the gearbox to transport the gearbox or geared
motor. Because they are designed only for the weight of the gearbox or geared motor, it is
not permissible to add additional loads.
Do not rig eyebolts to the front threads at the shaft ends for transportation purposes.
Do not use the integrally cast lifting eyes on the motor for transport because of the risk of
breaking.
If necessary, use additional, suitable lifting accessories for transport or during installation.
When attaching by a number of chains and ropes just two strands must be sufficient to bear
the entire load. Secure lifting accessories against slipping.
Table 11- 31 Maximum load of the eyebolt on the gearbox
Thread size
M8
M10
M12
M16
The eyebolt corresponds to DIN 580.
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
WARNING
m
kg
140
230
340
700
Additional information on the SIMOGEAR geared motor
d
Thread size
3
mm
36
M20
45
M24
54
M30
63
-
11.3 Specific data gearbox
m
d
3
kg
mm
1200
72
1800
90
3 200
108
-
-
441