Siemens SINAMICS G115D Operating Instructions Manual page 377

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Technical data of external braking resistor
The external braking resistors are not included in the scope of delivery of the G115D
converter. The following optional external braking resistors are available.
G115D wall-mounted
converter
Frame
Size
FSA
FSB
FSC
Peak power at 10% cycle time of a 120s cycle.
1)
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Rated power
Resistance
(+/-10%)
0.37 kW to 1.5 kW 210 Ω
220 Ω
200 Ω
2.2 kW to 4 kW
160 Ω
150 Ω
150 Ω
5.5 kW to 7.5 kW
81 Ω
72 Ω
10.2 Technical data of the G115D wall-mounted converter
External braking resistor
Continuous
Peak braking
braking power
power
200 W
1200 W
240 W
1440 W
480 W
2880 W
200 W
1200 W
240 W
1440 W
600 W
3600 W
600 W
3600 W
1200 W
7200 W
Technical data
Article number
1)
6SL3501-1BE32-0AA0
6SL3501-1BE32-4AA0
6SL3501-1BE34-8AA0
6SL3501-1BE32-0BA0
6SL3501-1BE32-4BA0
6SL3501-1BE36-0BA0
6SL3501-1BE36-0CA0
6SL3501-1BE41-2CA0
375