Simoloc Assembly System; General Notes For The Simoloc Assembly System - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

11.3.16

SIMOLOC assembly system

11.3.16.1

General notes for the SIMOLOC assembly system

Risk of injury due to freely rotating parts
Fit a cover cap or protection cover.
NOTICE
Damaged components impair the correct function of the gearbox
If any components are damaged, the correct function of the gearbox will no longer be
ensured.
Do not install any damaged gearbox components.
NOTICE
Lubricant on the machine shaft ① impairs the torque transmission
Keep the bore in the tapered bushing ⑨ and the machine shaft ① completely grease-free.
Do not use impure solvents and soiled cleaning cloths.
NOTICE
Avoid overloading the individual bolts
Do not exceed the maximum tightening torque for the tightening bolts ④ und ⑩.
Note
The SIMOLOC assembly system secures the hollow shaft axially on the machine shaft.
Note
In the hollow shaft ⑥, oil the locating hole for the tapered bushing ⑨ and bronze bushing ②
lightly with the provided oil.
Oil type of the provided oil: CLP VG 68 DIN 51517-3
Note
The thrust collar ⑤ must be placed at the correct position as in the delivered state.
Note
Before installing the SIMOLOC, mount the torque arms ⑦ on the gearbox.
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
WARNING
Additional information on the SIMOGEAR geared motor
11.3 Specific data gearbox
457